SAMR Issues Two Medical Metrology Calibration Specifications Taking Effect on 25 December

JJF 2425-2026 for carbon dioxide incubators and JJF 2426-2026 for pneumatic ballistic extracorporeal pressure wave therapy devices take effect on 25 December 2026. The first sets nine calibration points across three parameters; the second covers output intensity, penetration depth and collision frequency.

On 26 November 2026 the State Administration for Market Regulation (SAMR) announced the approval of two national metrology technical specifications: JJF 2425-2026, Calibration specification for carbon dioxide incubators, and JJF 2426-2026, Calibration specification for pneumatic ballistic extracorporeal pressure wave therapy devices. Both take effect on 25 December 2026. SAMR says the documents fill gaps in calibration rules for life science laboratories and rehabilitation equipment and provide a common metrological basis for medical institutions and testing bodies.

Carbon dioxide incubators simulate the internal biological environment for cell and tissue culture and are widely used in immunology, genetics and pharmacology; their metrological performance directly affects culture quality and diagnostic results. JJF 2425-2026 covers temperature, carbon dioxide concentration and relative humidity, arranging nine calibration points across upper, middle and lower levels and assessing indication error, uniformity and fluctuation. The default points are 37.0 degrees Celsius, 5.0 % carbon dioxide and 95 % RH, while commonly used set points may be selected to reflect actual working conditions, balancing consistency with practical operability.

Pneumatic ballistic extracorporeal pressure wave therapy devices act directly on the human body in rehabilitation, orthopaedics, pain management and traditional Chinese medicine therapy, so the accuracy of output parameters bears on patient safety. JJF 2426-2026 addresses three indicators: output intensity, assessed through the accuracy and stability of pressure wave output energy; penetration depth, assessed through the effective depth of action in tissue; and collision frequency, assessed through the rhythm of pressure wave application. The specification also states a scope boundary, excluding pneumatic ballistic lithotripters, which laboratories must check before accepting work.

The two specifications serve a dual purpose. For manufacturers they set a benchmark for design against clinical use and for factory performance control; for medical institutions and testing bodies they provide a common rule that makes calibration results comparable and traceable. SAMR plans organisation and training sessions and further specifications in medical metrology.

Four practical consequences follow for laboratories. First, scopes of accreditation or qualification need updating: a laboratory adding either specification must complete method validation, measurement uncertainty evaluation, verification of the traceability chain for reference instruments and authorisation of personnel. Second, carbon dioxide incubators are no longer assessed at a single point; uniformity and fluctuation must be recorded at upper, middle and lower positions, requiring revised record forms and data-processing procedures. Third, energy and frequency measurements on pressure wave devices involve dedicated loading and safety precautions, so working instructions and safety plans should be reviewed, with strict separation between therapy devices and lithotripters to avoid out-of-scope certificates. Fourth, with application starting on 25 December 2026, hospitals, disease control institutions and third-party laboratories should inventory equipment and schedule calibration ahead of the year-end rush. The official texts of the specifications prevail.

News & Insights

Certification

SAMR Questions 15 Electric Bicycle Makers after Full-Coverage CCC Certification Flight Inspections

On 27 November SAMR questioned 15 electric bicycle manufacturers including Yadea, Tailing and Aima. A full-coverage flight inspection of CCC certification had found weak quality responsibility and poor product consistency controls, with some companies selling nonconforming products in breach of mandatory national standards. The regulator demanded strict one-bike-one-battery-one-charger-one-code controls and immediate recalls of defective products.

Read more
Industry Governance

MEE Reports on Testing Body Oversight: Five Agencies Combat Data Fraud as Key Data from 17,000+ Vehicle Inspection Bodies Are Linked Nationally

At its 27 November press conference, the Ministry of Ecology and Environment reported that five agencies launched a crackdown on fraudulent environmental monitoring on 18 September. Self-inspection is complete and spot checks are under way, with dual penalties for institutions and individuals and information sharing on industry bans. Key data from more than 17,000 vehicle inspection bodies and 6.3 million heavy-duty vehicles are linked at three levels; over 1,400 unlawful bodies have been investigated and more than 50 have lost their qualifications in 2026.

Read more
Standards

ISO Publishes ISO/TR 24962:2026 on Sampling-Based Conformity Assessment Covering Processes, Lots and AI Classification Systems

ISO has published ISO/TR 24962:2026, Sampling-based conformity assessment, with status Published at stage 60.60; China’s national standards platform records the release date as 27 November 2026. The 74-page technical report from ISO/TC 69/SC 5 sets out how prior information can be used to design acceptance sampling plans, including for accuracy acceptance of AI classification systems.

Read more